Rev. Téc. Ing. Univ. Zulia. Vol. 44, Nº 2, May-August, 2021, 92-103 
 
Rev. Téc. Ing. Univ. Zulia. Vol. 44, No. 2, May-August, 2021. 
 
Experimental Behavior of Welded Connections between 
Square Steel Tubes Formed by G profiles of 60x30x10x2 and 
80x40x15x3 mm Subject to Monotonic Loads 
 
Carlos Alberto Romero Romero
1*
, Franklin Paul Verdugo Astudillo
1
, Julio 
Sebastián Bejarano Saritama
1
, José Domingo Alviar Malabet
1
, y Nelson 
Andrés López Machado
2  
 
1
Universidad Politécnica Salesiana, Avenida Morán Valverde y Rumichaca, PB EC170105, Quito, 
Ecuador 
2
Pontifica Universidad Católica, Santiago de Chile, 7560801, Chile  
*Corresponding author: cromero@ups.edu.ec 
https://doi.org/10.22209/rt.v44n2a04 
Received: 04 July 2020 | Accepted: 05 March 2021 | Available: 15 April 2021 
 
Abstract 
In  Ecuador,  the  use  of  square  tubular  steel  connections  has  increased  in  houses  and  shopping  centers. 
However,  there  is  no  regulation  that  explains  the  behavior  of  the  connection.  In  this research,  the  experimental 
behavior of this connection was evaluated. For this purpose, tests were carried out where the elastoplastic behavior of 
welded  joints  with  square  steel  tubes  formed  by  G  profiles  of  60x30x10x2  and  80x40x15x3  mm,  subject  to 
monotonic loads, were analyzed. Each test consisted of imposing  a progressive load on the frame upper node, in 
order to measure the displacements and distortion of the geometry of the beam-column join elements of the lower 
connection.  Results  show  that  the  experimental  collapse  load  in  frames  1,  2  and  3  (connection  without 
reinforcement) decreased  12.82 %  with respect to the theoretical  value,  while the collapse  in  frames  4, 5 and 6 
(reinforced connection) increased by 14.96 %. The reinforcement was constituted by platens installed in the column 
of the lower connection. With this, the failure due to local buckling has been avoided and the formation of plastic 
hinges in the beam of the welded joint has been guaranteed, thus fulfilling the criterion of weak beam-strong column. 
 
Keywords: monotonic load, welded connection, G profiles, plastic hinge. 
 
Comportamiento Experimental de Conexiones Soldadas entre 
Tubos Cuadrados de Acero Conformados por Perfiles G de 
60x30x10x2 y 80x40x15x3 mm Sometidas a Carga Monotónica 
 
Resumen  
En el Ecuador se ha incrementado el uso de conexiones con tubulares cuadrados de acero en viviendas y 
centros comerciales. Sin embargo, no existe una normativa que explique su comportamiento. En esta investigación se 
evaluó  el  comportamiento  experimental  de  dicha  conexión.  Para  ello,  se  realizaron  ensayos  donde  se  analizó  el 
comportamiento  elastoplástico  de  juntas  soldadas  con  tubos  cuadrados  de  acero  conformados  por  perfiles  G  de 
60x30x10x2 y 80x40x15x3 mm, sometidas a carga monotónica. Cada prueba consistió en imponer carga progresiva 
en la conexión superior del pórtico, para medir los desplazamientos y distorsión de la geometría de los elementos 
unión viga-columna de la conexión inferior. Los resultados evidencian que la carga de colapso experimental en los 
pórticos  1,  2  y 3 (conexión  sin refuerzo)  disminuyó  12,82  % con respecto al valor teórico,  mientras que en los 
pórticos 4, 5 y 6 (conexión reforzada) se incrementó en 14,96 %. El reforzamiento está conformado por platinas 
instaladas en la columna de la conexión inferior. Con ello, se ha evitado la falla por pandeo local y se ha garantizado 
la formación de rótulas plásticas en la viga de la unión soldada, cumpliendo  así el criterio de viga débil-columna 
fuerte. 
 
Palabras clave: carga monotónica, conexión soldada, perfiles G, rótula plástica.