'%3E%0A%3Cpath d='M-934.9 98.6H0v-26H-934.9v26Z' class='g0'/%3E%0A%3Cpath d='M0 98.6H935v-26H0v26Z' class='g0'/%3E%0A%3C/g%3E%0A%3Cpath d='M0 1169.7H935v-26H0v26Z' class='g0'/%3E%0A%3Cpath d='M301.8 658.6H437.7' class='g1'/%3E%0A%3Cpath d='M304.4 749.8H424.7M313.1 840.9H439.8' class='g2'/%3E%0A%3Cpath d='M210.2 932.1H343.9m-116.2 91.2H357.8m-109.9 91.1H374.8M705.1 199.3H836.5M648.4 323.5H790m-48.7 91.1H872.7M671.3 489.3H808.2m-66.9 91.1H872.7M545.8 688.1H682m-33.6 91.2H787M664.9 853.9H796.2M545.8 945.1H677.2' class='g1'/%3E%0A%3Cpath d='M644.3 1019.7H777.9' class='g2'/%3E%0A%3Cpath d='M701.3 1110.9H835.6' class='g1'/%3E%0A%3C/svg%3E)
_________________________________________________________________________________________________Revista Cientifica, FCV-LUZ / Vol.XXXV 
5 of 6 
CONCLUSION 
In this study, emdogain was applied to the sockets of the machined, 
RBM and SLA surface implants and its effect on osteointegration 
was evaluated. In the light of the results, similar to previous studies, 
the effect of emdogain application on osteointegration was found 
to be statistically significantly higher in implants with SLA surfaces 
compared to machine–made implants. In this case, it is seen 
that the surface roughness of the implants increases the rate of 
osteointegration. In order to obtain more definitive results; more 
advanced studies including histopathological, immunohistochemical 
and molecular analyses are needed. 
Conflict of interests 
The authors have no conflict of interests to declare concerning 
the authorship or publication of this article. 
Akcnowledgement 
The authors wish to thanks Implance Dental Implant System, 
AGS Medical Corporation, Istanbul, Turkiye. 
Funding 
There were no specific sources of funding for this research. 
BIBLIOGRAPHIC REFERENCES 
[1] Brånemark PI, Adell R, Breine U, Hansson BO, Lindström J, 
Ohlsson A. Intra–osseous anchorage of dental prostheses. 
I. Experimental studies. Scand. J. Plast. Reconstr. Surg. 
[Internet]. 1969; 3(2):81–100. doi: https://doi.org/drtkwh 
[2] Istek O, Tanrisever M, Atille Aydin M, Pak P, Eroksuz H, Karabulut 
B, Ekinci E, Dundar S. Evaluation of the effect of local bovine 
amniotic fluid on osseointegration of titanium implants: a 
histologic and histomorphometric study. Rev. Científ. FCV–LUZ. 
[Internet]. 2024; 34(2):e34417. doi: https://doi.org/n7nz 
[3] Istek O, Tanrisever M, Eroksuz H, Karabulut B, Ozcan EC, Bingul 
MB, Guler R, Dundar S: The histopathological evaluation of 
effects of application of the bovine amniotic fluid with graft on 
peri–implant bone regeneration. Kafkas Univ. Vet. Fak. Derg. 
[Internet]. 2023; 29(5):551–556. doi: https://doi.org/m854 
[4] Bingul MB, Gul M, Dundar S, Bozoglan A, Kirtay M, Ozupek 
MF, Ozcan EC, Habek O, Tasdemir I. Effects of the application 
local zoledronic acid on different dental implants in rats on 
osseointegration. Drug. Des. Devel. Ther. [Internet]. 2024; 
18:2249–2256. doi: https://doi.org/pmww 
[5] Özcan EC, Aydin MA, Dundar S, Tanrisever M, Bal A, Karasu N, 
Kirtay M. Biomechanical investigation of the osseointegration 
of titanium implants with different surfaces placed with 
allogeneic bone transfer. J. Craniofac. Surg. [Internet]. 2024; 
35(7):2184–2188. doi: https://doi.org/pmwx 
[6] Tekin B, Dundar S, Tekin S, Emine Sukuroglu E, Khurshid Z, Ezgi 
Y, Demirci F, Faheemuddin M. Effect of micro–arc oxidation 
coatings with graphene oxide and graphite on osseointegration 
of titanium implants–an in vivo study. Saudi Dent. J. [Internet]. 
2024; 36(4):591–595. doi: https://doi.org/pmwz 
[7] Sokmen N, Dundar S, Bozoglan A, Yildirim TT, Sokmen K, 
Sayeste E, Isayev A, Kirtay M. Effect of primary stabilisation 
on osseointegration of implants with local and systemic 
zoledronic acid application. J. Craniofac. Surg. [Internet]. 
2022; 33(5):1276–1281. doi: https://doi.org/pmw2 
[8] Miron RJ, Sculean A, Cochran DL, Froum S, Zucchelli G, 
Nemcovsky C, Donos N, Lyngstadaas SP, Deschner J, Dard 
M, Stavropoulos A, Zhang Y, Trombelli L, Kasaj A, Shirakata 
Y, Cortellini P, Tonetti M, Rasperini G, Jepsen S, Bosshardt 
DD. Twenty years of enamel matrix derivative: the past, the 
present and the future. J. Clin. Periodontol. [Internet]. 2016; 
43(8):668–683. doi: https://doi.org/f99nm2 
[9] Fidan I, Labreuche J, Huck O, Agossa K. Combination of 
enamel matrix derivatives with bone graft vs bone graft 
alone in the treatment of periodontal intrabony and furcation 
defects: a systematic review and meta–analysis. Oral Health 
Prev. Dent. 2024; 22:655–664. doi: https://doi.org/pmw3 
[10] Qiao T, Yi Y, Kang Z, Huang Z, Wan J, Wang Y, Qian C. 
Recombinant human amelogenin promotes wound healing 
by enhancing angiogenesis. Biochem. Biophys. Res. Commun. 
2024; 734:150462. doi: https://doi.org/gt826n 
[11] Vela OC, Boariu M, Rusu D, Iorio–Siciliano V, Sculean A, 
Stratul SI. Clinical and Radiographic Evaluation of Intrabony 
Periodontal Defects Treated with Hyaluronic Acid or Enamel 
Matrix Proteins: A 6–Month Prospective Study. Oral Health 
Prev. Dent. 2024; 22:257–270. doi: https://doi.org/pmw4 
[12] Miron RJ, Bosshardt DD, Buser D, Zhang Y, Tugulu S, Gemperli 
A, Dard M, Caluseru OM, Chandad F, Sculean A. Comparison 
of the capacity of enamel matrix derivative gel and enamel 
matrix derivative in liquid formulation to adsorb to bone 
grafting materials. J. Periodontol. 2015; 86(4):578–587. 
doi: https://doi.org/f67ndv 
[13] Dierens M, Vandeweghe S, Kisch J, Nilner K, De Bruyn H. 
Long–term follow–up of turned single implants placed in 
periodontally healthy patients after 16–22 years: radiographic 
and peri–implant outcome. Clin. Oral Implants Res. 2012; 
23(2):197–204. doi: https://doi.org/cw7rjm 
[14] Dundar S, Yaman F, Bozoglan A, Yildirim TT, Kirtay M, 
Ozupek MF, Artas G. Comparison of osseointegration of five 
different surfaced titanium implants. J. Craniofac. Surg. 2018; 
29(7):1991–1995. doi: https://doi.org/pmw5 
[15] Ozcan EC, Gul M, Dundar S, Bozoglan A, Karasu N, Bal A, Gunes 
N, Bingul MB. Effects of local application of the ankaferd blood 
stopper on osseointegration in three different surface titanium 
implants. J. Oral Biol. Craniofac. Res. 2021; 11(4):524–528. 
doi: https://doi.org/pmw6 
[16] Miron RJ, Wei L, Yang S, Caluseru OM, Sculean A, Zhang Y. Effect 
of enamel matrix derivative on periodontal wound healing and 
regeneration in an osteoporotic model. J Periodontol. 2014; 
85(11):1603–1611. https://doi.org/f6pv86 
[17] Boyan BD, Weesner TC, Lohmann CH, Andreacchio D, Carnes DL, 
Dean DD, Cochran DL, Schwartz Z. Porcine fetal enamel matrix 
derivative enhances bone formation induced by demineralized 
freeze dried bone allograft in vivo. J. Periodontol. [Internet]. 
2000; 71(8):1278–1286. doi: https://doi.org/fcxwqn