
This scientic publication in digital format is a continuation of the Printed Review: Legal Deposit pp 196802ZU42, ISSN 0378-7818.
  Rev. Fac. Agron. (LUZ). 2022, 39(2): e223926. April - June. ISSN 2477-9407.
4-4 |
Block Installation
The physical characteristics of the soil, determined in the 
lysimeters, indicate that it has a silty-loam texture, which coincide 
with those of the soil evaluated around the lysimeters (Table 1).
The  average  inltration  rate  in  the  block  ranged  from  1000 
mm.h
-1
 in the rst 10 minutes to 7 mm.h
-1
 at 280 minutes, with a 
correlation coefcient of 0.9. The speed decreases with depth and 
the level of compaction present, which coincides with Villazón et 
al. (2015), who obtained high levels of compaction at 0.30 m and 
therefore  decreased  water  inltration. On  the other  hand,  Denioa 
et al. (2011) observed for a silty loam soil, such as the type of the 
present work, that inltration decreases in compacted soils.
A chemical analysis of the soil was carried out in each lysimeter, 
the  results  coincide  with  those  determined  by  Rioja  (2002).  The 
organic matter (OM) content is scarce, the electrical conductivity 
(EC) is inestimable, the potential hydrogen pH) is moderately basic, 
the phosphorus (P) low, the potassium (K) and calcium very low, 
and the magnesium (mg) very high.
Lysimeter Block Calibration
Once the irrigation corresponding to each lysimeter was carried 
out until reaching the eld capacity and the additional irrigation, to 
induce drainage, it was obtained that the lysimeters from one to ve 
needed 25 % of the CC, of   over-irrigation, while the rest needed 50 
%. The (soil moisture content in the 3 layers was: layer 1 (21.74 %), 
layer 2 (6.25 %) and layer 3 (8.33 %). The volume required to reach 
eld capacity in each of them was 0.07 m
3
, 0.32 m
3
 and 0.32 m
3
, 
respectively, for a total volume in the entire lysimeter of 0.71 m
3
.
Conclusions
A protocol is available for the design, construction and 
calibration of drainage lysimeters for the determination of the crop 
coefcient (Kc).
The lysimeters from one to ve needed 25 % of the CC, of over 
irrigation, the rest needed 50b%, a total volume of water of 0.71 m3 
was required to reach eld capacity.
Table 1. Physical parameters of the soil determined in the lysimeters.
Lysimeter
Compactcion
 
(kgf/cm
2
)
Inltration 
rate
 
(mm.h
-1
)
Apparent 
density 
(kg.L
-1
)
Field 
capacity
 (%)*
Permanent 
wilting point (%)*
Texture*
1
4.90 104.17 1.48
28.34
10.11 Silty loam
2
5.64 108.33 1.40
28.34
10.11 Silty loam
3
5.12 102.11 1.50
28.34
10.11 Silty loam
4
5.16 115.61 1.43
28.45
9.68 Silty loam
5
5.17 144.40 1.38
28.45
9.68 Silty loam
6
5.08 79.96 1.45
28.45
9.68 Silty loam
7
5.23 104.83 1.42
28.77
10.00 Silty loam
5.19 108.49 1.44
28.02
9.91
Literature cited
Bochetti V., M. J. 2010. Análisis comparativo de la evapotranspiración obtenida 
mediante distintas ecuaciones empíricas aplicadas a la zona agrícola 
de Chillan.  Tesis de grado. Universidad Católica de la Santísima 
Concepción.  Concepción,  Chile.  Disponible  en:  http://web2.ucsc.
cl/~civil/investigacion/memorias/mbochetti.pdf
Chávez, S. y Mesías, D. 2018. Evaluación de tres métodos para determinar el 
requerimiento hídrico, del cultivo de maíz (Zea mays. L.) var INIAP 102, 
cantón Riobamba, provincia de Chimborazo. (Tesis de grado. Ingeniero 
Agrónomo). Escuela Superior Politécnica de Chimborazo. Riobamba. 
Disponible en: http://dspace.espoch.edu.ec/handle/123456789/10351
Denioa, J., Sosa, O., Zerpa, G. y Martín, B. 2011. Efecto del pisoteo animal 
sobre la velocidad de inltración y sobre otras propiedades físicas del 
suelo.  Pastos,  30(1): 129-141. Disponible en: http://polired.upm.es/
index.php/pastos/article/view/1278
Ekanayake, I. 1994. CIP Research 30, studying drought stress and irrigation 
requirements of potatoes. Lima -Perú. Disponible en: https://pdf.usaid.
gov/pdf_docs/pnabs379.pdf
FAO 2008. El cambio climático y la producción de alimentos. Disponible en: 
ftp://ftp.fao.org/docrep/fao/010/i0112s/i0112S03.pdf.
García V., J., Huahuachampi, J. y Soto, L. 2017. Determinación de la demanda 
hídrica del cultivo de quinua QML01 (Chenopodium quinoa Willd) en 
la Molina. Anal. Cient. 78(2): 200-209.  Disponible en: http://dx.doi.
org/10.21704/ac.v78i2.1057
García, M. 2017. Lisímetros. In Agencia Catalana del Agua. Barcelona, 
España. p. 4.
León Ruíz, J. E. 2016. Modelación matemática para estimar los requerimientos 
hídricos del cultivo de papa (Solanum spp.) en Riobamba-Ecuador. 
(Tesis de posgrado. Doctoris Philosophie en Recursos Hídricos). 
Universidad Nacional Agraria La Molina. Perú. Disponible en: http://
repositorio.lamolina.edu.pe/handle/UNALM/2833
León Ruíz, J. E. 2012. Riegos y Drenajae.1
ª
 ed. Centro Experimental de Riego, 
ESPOCH, Riobamba, Ecuador
Nelson, G., M. Rosegran, J. Koo, R. Robertson, T. Sulser, T. Zhu, C. Ringler, S. 
Msangi, A. Palazzo, M. Batka, M. Magalhane, R. Valmonte-Santos, M. 
Ewing y D. Lee. 2009.  Cambio climático: El impacto en la agricultura y 
los costos de adaptación. Instituto Internacional de Investigación sobre 
Políticas  Alimentarias  IFPRI,  Washington,  D.C.  20  pp.  Disponible 
en:  http://www.fao.org/leadmin/user_upload/AGRO_Noticias/docs/
costo%20adaptacion.pdf
Paguay C., S. C. 2017. Determinación de los requerimientos hídricos para el 
cultivo de la cebolla colorada (Allium cepa L.) Var. Burguesa en base al 
contenido de agua en el suelo, en Macají, cantón Riobamba, provincia 
de Chimborazo  (Tesis de grado. Ingeniero Agrónomo). Escuela 
Superior Politécnica de Chimborazo. Riobamba, Ecuador. Disponible 
en: http://dspace.espoch.edu.ec/handle/123456789/7643
Rioja, A. 2002. Apuntes de Fitotecnia General. Escuela de Ingenieros 
Agrónomos de Ciudad Real E.U.I.T.A. Ciudad Real. Universidad de 
Castilla-La Mancha, España. 
Villa F., G.  2014.  A propósito de la gestión del agua en el mundo contemporáneo.  
Un enfoque biopolítico. Anal. Polit. 74, 109 - 133. https://revistas.unal.
edu.co/index.php/anpol/article/view/43721
Villazón, J. A., Martín, G., Rodríguez, Y. y Cobo, Y. 2015. Resistencia a la 
penetración en un Vertisol Crómico con diferentes usos, manejos y sitios 
de muestreo. Pastos y Forrajes. 38(2), 162-169. ISSN: 0864-0394. 
Disponible en: https://www.redalyc.org/articulo.oa?id=269139251002}